Rev. urug. cardiol ; 38(1): e407, 2023. ilus
Artigo em Espanhol | LILACS, BNUY, UY-BNMED | ID: biblio-1530365

RESUMO

El uso de la resonancia magnética (RM) en las distintas áreas de la medicina se ha expandido de manera significativa y de forma diaria se solicitan numerosos estudios. El hecho de que los resonadores pueden interaccionar con algunos objetos ha llevado a que históricamente se les niegue la realización de este estudio a pacientes portadores de dispositivos cardíacos porque se entiende que existen contraindicaciones absolutas. El avance de la tecnología de los dispositivos y la creciente evidencia publicada han cambiado este concepto. Nos proponemos revisar los mecanismos por los cuales un dispositivo implantable puede interactuar con el resonador y las implicancias clínicas que esto podría tener si las hubiera. La mayoría de los pacientes portadores de dispositivos cardíacos de estimulación podrán realizarse una RM, pero para que este procedimiento sea seguro es importante conocer las características y el tipo específico de dispositivo implantado. Proponemos finalmente puntos clave y algoritmos para tener en cuenta para el manejo adecuado de estos pacientes.


The use of magnetic resonance imaging (MRI) in different areas of medicine has expanded significantly and numerous procedures are indicated daily. The fact that resonators could interact with some objects has historically led to patients with cardiac devices being denied an MRI on the understanding that they suppose an absolute contraindication. Advances in device technology and the increasing evidence have changed this concept. We intend to review the mechanisms by which an implantable device could interact with the resonator and the clinical implications that this could have if any. Most patients will be able to undergo these studies, but to determine the safety of performing an MRI it is important to know the characteristics and specific type of implanted device. Finally, we provide key points and algorithms to take into account for these patients.


O uso da ressonância magnética em diferentes áreas da medicina tem se expandido significativamente e inúmeros exames são indicados diariamente. A possibilidade de que os ressonadores interajam com alguns objetos historicamente levou os pacientes com dispositivos cardíacos a terem a ressonância magnética negada por entender que existem contraindicações absolutas. Os avanços na tecnologia de dispositivos e o aumento das evidências publicadas mudaram esse conceito. Pretendemos revisar os mecanismos pelos quais um dispositivo implantável pode interagir com o ressonador e as implicações clínicas que isso pode ter, se houver. A grande maioria dos pacientes poderá se submeter a esses estudos, mas para determinar a segurança de realizar uma ressonância magnética é importante conhecer as características e o tipo específico de dispositivo implantado. Por fim, propomos pontos e algoritmos para a gestão dos pacientes.


Assuntos
Humanos , Marca-Passo Artificial , Imageamento por Ressonância Magnética/efeitos adversos , Espectroscopia de Ressonância Magnética/efeitos adversos , Desfibriladores Implantáveis , Administração dos Cuidados ao Paciente
4.
Braz J Anesthesiol ; 70(3): 302-305, 2020.
Artigo em Português | MEDLINE | ID: mdl-32473832

RESUMO

BACKGROUND AND OBJECTIVES: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a genetic cardiomyopathy characterized by potentially lethal ventricular tachycardia. Here we describe a patient with ARVC and an Implantable Cardioverter Defibrillator (ICD) in whom maxillary sinus surgery was performed under general anesthesia. CASE REPORT: The patient was a 59 year-old man who was scheduled to undergo maxillary sinus surgery under general anesthesia. He had been diagnosed as having ARVC 15 years earlier and had undergone implantation of an ICD in the same year. Electrocardiography showed an epsilon wave in leads II, aVR, and V1-V3. Cardiac function was within normal range on transthoracic echocardiography. The ICD was temporarily deactivated after the patient arrived in the operating room and an intravenous line was secured. An external defibrillator was kept on hand for immediate defibrillation if any electrocardiographic abnormality was detected. Remifentanil 0.3 µg/kg/min, fentanyl 0.1 mg, propofol 154 mg, and rocuronium 46 mg were administered for induction of anesthesia. Tracheal intubation was performed orally. Anesthesia was maintained oxygen 1.0 L.min-1, air 2.0 L.min-1, propofol 5.0-7.0 mg.kg-1.h-1, and remifentanil 0.1-0.25 µg.kg-1.min-1. The surgery was completed as scheduled and the ICD was reactivated. The patient was then extubated after administration of sugammadex 200 mg. CONCLUSION: We report the successful management of anesthesia without lethal arrhythmia in a patient with ARVC and an ICD. An adequate amount of analgesia should be administered during general anesthesia to maintain adequate anesthetic depth and to avoid stress and pain.


Assuntos
Anestesia , Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Seio Maxilar/cirurgia , Displasia Arritmogênica Ventricular Direita/complicações , Humanos , Masculino , Pessoa de Meia-Idade
5.
Rev. bras. anestesiol ; 70(3): 302-305, May-June 2020. graf
Artigo em Inglês, Português | LILACS | ID: biblio-1137181

RESUMO

Abstract Background and objectives: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a genetic cardiomyopathy characterized by potentially lethal ventricular tachycardia. Here we describe a patient with ARVC and an Implantable Cardioverter Defibrillator (ICD) in whom maxillary sinus surgery was performed under general anesthesia. Case report: The patient was a 59 year-old man who was scheduled to undergo maxillary sinus surgery under general anesthesia. He had been diagnosed as having ARVC 15 years earlier and had undergone implantation of an ICD in the same year. Electrocardiography showed an epsilon wave in leads II, aVR, and V1-V3. Cardiac function was within normal range on transthoracic echocardiography. The ICD was temporarily deactivated after the patient arrived in the operating room and an intravenous line was secured. An external defibrillator was kept on hand for immediate defibrillation if any electrocardiographic abnormality was detected. Remifentanil 0.3 µg/kg/min, fentanyl 0.1 mg, propofol 154 mg, and rocuronium 46 mg were administered for induction of anesthesia. Tracheal intubation was performed orally. Anesthesia was maintained oxygen 1.0 L.min−1, air 2.0 L.min−1, propofol 5.0-7.0 mg.kg−1.h−1, and remifentanil 0.1-0.25 µg.kg−1.min−1. The surgery was completed as scheduled and the ICD was reactivated. The patient was then extubated after administration of sugammadex 200 mg. Conclusion: We report the successful management of anesthesia without lethal arrhythmia in a patient with ARVC and an ICD. An adequate amount of analgesia should be administered during general anesthesia to maintain adequate anesthetic depth and to avoid stress and pain.


Resumo Introdução e objetivo: A Cardiomiopatia Arritmogênica do Ventrículo Direito (CAVD) é uma cardiomiopatia genética caracterizada por taquicardia ventricular potencialmente letal. Descrevemos um paciente com CAVD com Cardioversor Desfibrilador Implantável (CDI) submetido a anestesia geral para cirurgia de seio maxilar. Relato do caso: Paciente masculino, 59 anos, a ser submetido a anestesia geral para cirurgia de seio maxilar. O paciente foi diagnosticado com CAVD há 15 anos, momento em que foi submetido a implante de CDI. A eletrocardiografia mostrou onda épsilon nas derivações II, aVR e V1-V3. O ecocardiograma transtorácico revelou função cardíaca normal. Após a entrada do paciente na sala de cirurgia, o CDI foi temporariamente desativado e uma via intravenosa foi instalada. Um desfibrilador externo foi mantido próximo ao paciente caso fosse detectada alguma anormalidade eletrocardiográfica que indicasse desfibrilação do paciente. Foram administrados 0,3 mg/kg/min de remifentanil, 0,1 mg de fentanil, 154 mg de propofol e 46 mg de rocurônio para indução da anestesia. A intubação traqueal foi realizada por via oral. A anestesia foi mantida com 1 L/min de oxigênio, 2 L/min de ar, 5-7 mg/kg/h de propofol e 0,1-0,25 µg/kg/min de remifentanil. O procedimento cirúrgico proposto foi concluído e o CDI foi reativado. O tubo traqueal foi retirado após administração de 200 mg de sugamadex. Conclusão: Descrevemos técnica de anestesia bem sucedida sem arritmia letal em paciente com CAVD e CDI. Analgesia adequada deve ser administrada durante a anestesia geral para manter profundidade anestésica correta e evitar estresse e dor.


Assuntos
Humanos , Masculino , Desfibriladores Implantáveis , Displasia Arritmogênica Ventricular Direita/complicações , Anestesia , Seio Maxilar/cirurgia , Pessoa de Meia-Idade
6.
Rev Port Cardiol ; 35(7-8): 407-12, 2016.
Artigo em Inglês, Português | MEDLINE | ID: mdl-27396627

RESUMO

The authors present the results of the national registry of electrophysiology of the Portuguese Association for Arrhythmology, Pacing and Electrophysiology (APAPE) for 2013 and 2014. The registry is annual and voluntary, and data are collected retrospectively. Data for electrophysiological studies, ablations and cardioverter-defibrillator implantations for 2013 and 2014 are presented. Developments over the years and their implications are analyzed and discussed.


Assuntos
Ablação por Cateter/estatística & dados numéricos , Desfibriladores Implantáveis/estatística & dados numéricos , Eletrocardiografia/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Humanos , Portugal , Sociedades Médicas
7.
Rev Port Cardiol ; 34(3): 211.e1-3, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25707735

RESUMO

We report the case of a young man who accidentally received a prolonged electric discharge from electrical wires and released the electric source with the help of an inappropriate shock from his implantable cardioverter-defibrillator (ICD), after misinterpretation of the electrical signal by the device as a ventricular tachycardia. This case illustrates the "electrical noise" phenomenon, and underscores the need for precautions for patients with an ICD and their physicians.


Assuntos
Desfibriladores Implantáveis , Adulto , Eletricidade/efeitos adversos , Humanos , Masculino , Falha de Prótese
8.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 27(1): 22-26, jan.-mar.2014.
Artigo em Português | LILACS | ID: lil-767315

RESUMO

A cardiopatia chagásica crônica (CCC) ainda é um importante problema de saúde pública no Brasil. A principal causa de óbito é a morte súbita por taquiarritmia e o cardioversor-desfibrilador implantável (CDI) tornou-se importante opção terapêutica nessa doença. Objetivos: Identificar os pacientes com CCC, portadores de CDI, que receberam terapia de choque e reconhecer o principal mecanismo arritmogênico deflagrador. Metodologia: Estudo descritivo, retrospectivo, com amostra de 81 pacientes portadores de CDI. Os dados relacionados a eventos arrítmicos e terapias foram obtidos retrospectivamente pela análise dos eletrocardiogramas endocavitários (EGM) de cada paciente. Os resultados foram expressos em valores absolutos, médias e porcentagem, em tabelas e gráficos. Resultados: Foram documentadas terapias apropriadas em 68 (83,9%) pacientes, com um total de 5.336 eventos. Desses, 4.585 (85,9%) foram apenas trem de pulso (ATP) e 741 (14,1%), choques subsequentes ou não à falência do ATP. A taquicardia ventricular monomórfica (TVM) foi a arritmia mais diagnosticada nos EGM, com 4.783 (89,6%) eventos, seguida de taquicardia ventricular polimórfica (TVP) em 480 (8,9%) e fibrilação ventricular (FV) em apenas 63 (1,5%). Conclusões: Demonstrou-se elevada prevalência (83,9%) de pacientes chagásicos portadores de CDI submetidos a terapias por esse dispositivo. Além disso, detectou-se que o principal mecanismo arritmogênico deflagrador de choque foi a TVM na zona de taquicardia rápida, secundária à aceleração da frequência cardíaca após terapia por ATP ineficaz...


Chronic Chagas’ cardiomyopathy remains a major public health problem in Brazil. Tachyarrhythmia is the leading cause of sudden death and the implantable cardioverter defibrillator (ICD) has become an important therapeutic option. Objectives: Identify patients with CCC and ICD who have received shock therapy and identify the main arrhythmogenic mechanism triggering shock in these patients. Method: Retrospective descriptive study, with a sample of 81 patients undergoing CDI implantation from January 2004 to December 2007. Data were obtained retrospectively by analysis of patients’ intracavitary electrocardiograms (iECM). Results were expressed as absolute numbers, mean and percentage values, using tables and graphs. Results: Appropriate therapy was documented in 68 (83.9%) patients, with a total of 5,336 events. Of these, 4,585 (85.9%) were only train of pulse (ATP) and 741 (14.1%) were shocks subsequent or not to failure of ATP. Monomorphic ventricular tachycardia (MVT) was the most frequently diagnosed arrhythmia in the iECGs with 4,783 (89.6%) events, followed by polymorphic ventricular tachycardia (TVP) with 480 (8.9%) and ventricular fibrillation (VF) with only 63 (1.5%). Conclusion: This study demonstrated a high prevalence (83.9%) of chagasic patients receiving ICD therapy. Furthermore, the main arrhythmogenic mechanism triggering shock in these patients was MVT in the zone of fast tachycardia secondary to heart rate acceleration after failure of ATP therapy...


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Arritmias Cardíacas/diagnóstico , Cardiomiopatia Chagásica/diagnóstico , Desfibriladores Implantáveis , Ecocardiografia , Epidemiologia Descritiva , Eletrocardiografia/métodos , Fatores de Tempo
9.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 27(1): 53-57, jan.-mar.2014.
Artigo em Português | LILACS | ID: lil-767321

RESUMO

Relata-se o caso de uma criança com síndrome do QT longo congênito e Tetralogia de Fallot, submetidaa denervação simpática por videotoracoscopia, para controle de tempestades arrítmicas e diminuição do númerode choques do cardioversor-desfibrilador implantável...


We report the case of a child with congenital long QT syndrome and Tetralogy of Fallot submittedto sympathetic denervation by videolaparoscopy to control arrhythmic storms and decrease the number ofimplantable cardioversor-defibrillator chocks...


Assuntos
Humanos , Criança , Arritmias Cardíacas/complicações , Síndrome do QT Longo/terapia , Tetralogia de Fallot/terapia , Desfibriladores Implantáveis , Ecocardiografia , Eletrocardiografia Ambulatorial , Simpatectomia/enfermagem
10.
Ribeirão Preto; s.n; ago. 2012.
Tese em Português | Index Psicologia - Teses | ID: pte-53904

RESUMO

Ser cuidador informal de pacientes com doenças crónicas pode Implicar em sobrecarga e sofrimento psicológico significativo, potencialmente prejudiciais para a própria saúde física e mental e para a recuperação do paciente. Pouco se sabe sobre as experiências e características psicossociais dos cuidadores de pacientes portadores de Cardioversor Desfibrilador Implantável (CDI), principalmente na população brasileira, de forma que o presente estudo (quantitativo descritiva transversal) teve por objetivos caracterizar demográfica e psicossocialmente uma amostra não probabilística de cuidadores informais de pacientes portadores de CDI que se encontravam em tratamento medico em um hospital-escola do Interior do Estado de São Paulo. As variáveis estudadas incluíram: características sóciodemograficas, qualidade de vida ansiedade, depressão e percepção de sobrecarga. Participaram da pesquisa 60 cuidadores, entrevistados entre Setembro de 2010 a maia de 2011. Para a coleta dos dados foram usados: Roteiro de Entrevista Semiestruturada elaborado para esta pesquisa, Questionário de Avaliação de Saúde SF-36, Escala Hospitalar de Ansiedade e Depressão e a Zarlt Burden Interview. Os dados foram analisados quantitativamente de forma descritiva Posteriormente verificou-se associação estatisticamente significativa (p<0,05) entre algumas variáveis de Interesse, por meio do Teste Exato de Fisher. Os resultados mostraram que a média de idade dos cuidadores foi de 52,5 amos (DP 14,76), eram em sua maior parte do sexo feminino (n 45, 750/D), o cônjuge do(a) paciente (n=39, 65%), com escolaridade predominante de ate quatro amos (n=28, 46,67%) sendo a maioria (45, 75%) portadora de problemas de saúde. Vinte e cinco cuidadores (41,67%) apresentaram sintomas indicativos de ansiedade e 13 (21,67%) de depressão...(AU)


Bering an informal caregiver of patients with chronic diseases may imply significant psychological burden and suffering, potentially harmful to caregiver’s own physical and mental health and patient’s recovery. Little is known about the psychosocial experiences and characteristics of caregivers of patients with Implantable Cardioverter Defibrillator (ICD), mainly m the Brazilian population, so that the purpose of the present study (transversal descriptive quantitative) was to characterize, both demographically and psychosocially, a nonprobabilistie sample of informal caregivers of patients with ICD undergoing treatment m a university hospital in the anterior of the State of Sao Paulo. The studied variables comprised: sociodemographic characteristics, life quality, anxiety, depression amd perception of burden. Sixty caregivers took part m the survey, and they were interviewed between September, 2010 and May, 2011. Data collection used the following instruments: Semi-structured interview Script prepared for this survey, SF-36 Health Evaluation Questionnaire, Hospital Anxiety and Depression Scale and the Zarit Burden interview. Data was analyzed quantitatively m a descriptive way. Subsequently, statistically significant association (p≤0,05) was verified between some variables of interest through Fisher’s Exact Test. Results describe that the average age of caregivers was 52.5 years (DP 14.76), they were mostly female (n 45, 75%), and patient’s spouses (n=39, 65%), predominantly with up to four years of education (n=28, 46.67%), and most (45, 75%) with health problems. Twenty-five caregivers (41.67%) presented symptoms related to anxiety and 13 (21.67°/r) to depression...(AU)

11.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 23(1): 18-23, jan-mar.2010.
Artigo em Português | LILACS, Sec. Est. Saúde SP | ID: lil-560313

RESUMO

A estimulação cardíaca artificial com o uso de cardioversor-desfibrilador implantável (CDI) é uma das alternativas para o tratamento das arritmias ventriculares e da morte súbita. O uso do CDI gera dúvidas nos portadores, o que pode afetar o tratamento. Este estudo teve por objetivo identificar dúvidas de pacientes no pós-operatório de implante de CDI em relação ao tratamento. Métodos: Estudo descritivo-exploratório com abordagem quanti-qualitativa, realizado em uma instituição pública da cidade de São Paulo, especializada em afecções do sistema cardiovascular. A coleta foi realizada da entre dezembro 2006 e agosto 2007 e respeitou os preceitos éticos de pesquisa. A amostra foi constituída por portadores de doença cardiovascular, na faixa etária de 60 a 70 anos, em sua maioria do sexo masculino (85%). Resultados: Quanto às respostas relacionadas aos conhecimentos sobre o CDI, 71% dos pacientes desconheciam sua funcionalidade, as razões, o local e a forma do implante. Todos apresentaram dúvidas sobre a possibilidade de interferências externas ocasionadas por telefone fixo ou celular, televisor e dispositivos eletrônicos instalados em porta de banco. As demais dúvidas diziam respeito a interferências devidas a: uso de transporte coletivo (73%), durabilidade da bateria (66%), aparelhos de som (42%), microondas (42%), choques elétricos (26%), uso de elevadores (26%), colchões magnéticos (11%), furadeiras elétricas (6,6%) e viagens de avião (2,2%). Quando questionados se gostariam de receber um manual de orientação em relação ao procedimento e ao tratamento com o CDI, 100% responderam afirmativamente. Conclusão: Acredita-se que a elaboração de um manual de orientações contribuirá para a educação em saúde desses pacientes, fornecendolhes instruções e experiências de aprendizagem que facilitem seu dia-dia. Além disso,...


Implantable cardioverter-defibrillators (ICD) is one of the therapy alternatives to prevent ventricular arrhythmia and sudden cardiac death. The use of ICD raises some doubts for the users whichmay indirectly affect the therapy. The aim of this study is to identify the doubts about the therapy that the patients in the ICD implantation post-operative may have and to propose a reference manual. Methods: It is an exploratory-descriptive study with a quantify-qualifying approach performed at a public institution that is specialized in affections of the cardiovascular system, in the state of São Paulo, Brazilwhose motto is: research, teaching and assistance. The sample was collected between December 2006 and August 2007, respecting ethics precepts of the research and it was composed by 45 patients with heart disease, age of major incidence 60-70 years. The population was composed mostly by male patients (85%). Results: As to the answers related to ICD, in spite of all the information available in the programs about the meaning of the recommended therapy orientation, 71% of the patients did not know about thenormal function of their device, where, why or how it was implanted. They all had questions as to whether or not mobile and conventional phones, television, automatic doors, and so on, could have any electromagneticinterference. Other questions were basically about interference from the use of public transportation (73%), battery durability (66%), stereo systems (42%), microwave ovens (42%), electric shocks (26%),elevators (26%), magnetic beds (11%), electric drills (6.6%), and 2.2% air travel. When asked if they would like to receive a reference manual of the ICD procedures and treatment, 100% responded positively. Conclusion: Evidently, the development of a reference manual will contribute a great deal with the health education of the patients by providing them with knowledge to cope with everyday activities. In addition to that,...


La estimulación cardiaca artificial con el uso de cardioversor-desfibrilador implantable (CDI) es una de las alternativas para el tratamiento de las arritmias ventriculares y la muerte súbita. El empleo del CDI genera dudas a los portadores, lo que puede afectar el tratamiento. Este estudio tuvo por objetivo identificar dudas de pacientes en el post-operatorio de implante de CDI con relación al tratamiento. Métodos: Estudio descriptivo-exploratorio con abordaje cuanti-cualitativo, llevado a cabo en una institución pública de la ciudad de São Paulo, especializada en afecciones del sistema cardiovascular. La recolección se realizó entre diciembre de 2006 y agosto de 2007 y respetó los preceptos éticos de investigación. La muestra fue constituida por portadores de enfermedad cardiovascular, en la franja etaria de 60 a 70 años, en su mayoría del sexo masculino (85%). Resultados: En cuanto a las respuestasrelacionadas con los conocimientos sobre el CDI, el 71% de los pacientes desconocían su funcionalidad, las razones, el sitio y la forma del implante. Todos presentaron dudas sobre la posibilidad de interferenciasexteriores ocasionadas por teléfono fijo o celular, televisor y dispositivos electrónicos instalados en las puertas de los bancos. Las demás dudas se referían a las interferencias debidas a: uso de transporte colectivo (73%), durabilidad de la batería (66%), estéreos (42%), microondas (42%), choques eléctricos (26%), uso de elevadores/ascensores (26%), colchones magnéticos (11%), taladradoras (6,6%) y viajes en avión (2,2%). Cuando cuestionados si les gustaría recibir un manual de orientación respecto delprocedimiento y el tratamiento con el CDI, el 100% contestaron afirmativamente. Conclusión: Se creeque la elaboración de un manual de orientaciones contribuirá a la educación en salud de esos pacientes al brindarles instrucciones y experiencias de aprendizaje que faciliten su día a día. Además,...


Assuntos
Humanos , Masculino , Feminino , Adolescente , Idoso , Arritmias Cardíacas , Desfibriladores Implantáveis , Marca-Passo Artificial/história
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...